
Chase Cover Replacement in Cypress, Flue Checked Below
What Burns Below the Flue?
Wood, gas, pellets or an insert: name it, add the job you have in mind, and a Seymour scheduler phones back to plan the camera visit.
Inside This Job
On a prefab fireplace, the metal top of the chase is the roof over the whole flue enclosure. When it rusts or holds a puddle, water seeps through to the plywood, and the camera often finds rust streaks on the flue pipe itself. Seymour measures the top, orders a stainless cover with cross breaks and a drip hem, seals the joint where the pipe passes through, and checks the cap above it.
What Sits Inside a Chase
Plenty of Cypress chimneys have no masonry in them at all. Behind the fireplace sits a steel firebox from a factory, and its exhaust climbs through a round steel pipe. The boxy column you see outside is carpentry built around that pipe, and its top is closed by a sheet metal lid that the pipe pokes through, with a storm collar and a cap stacked on it. That lid keeps every drop of rain out of the enclosure. When it was made from thin galvanized sheet, as many were, it rusts, sags in the middle and holds water, and the water finds the seams and the collar. From there it runs down inside the chase, onto the metal flue, the framing and the insulation, and finally the top of the fireplace. Rust streaks down the side of the chase and stains on the ceiling near the fireplace are the usual signs.
What the eye cannot see is the condition of the metal flue inside, and that is where we put the camera. Factory built flues are tested and sold as a set with their fireplace, and they are only safe while the sections stay locked together and the metal stays sound. Water coming in at the top can rust the pipe, the joints and the firestops where the pipe passes the floors and ceilings. On camera, a healthy pipe looks bright and continuous. A damaged one shows rust patches, a section that has dropped away from the one above, or a seam that has opened. We check the pipe, the collar where it meets the chase top, the cap above, and the framing inside the chase as far as we can reach, before we write anything up.
The Replacement and the Quote
A new chase top is built to the dimensions of your enclosure, out of stainless or another metal that will not rust the way thin galvanized does. Its surface is formed to shed water toward the edges, and its skirt laps the outer walls of the enclosure with a kicked out hem, so runoff leaves the metal before it reaches the stucco. The opening for the pipe is cut where your pipe actually sits, and a collar and cap made for your flue system go on above. Where the old lid has let water in for some time, we also look at the wood at the top of the chase, and replace rotted framing or sheathing before the new top goes on. The pipe itself is checked again once the top is off, since no other moment gives as clear a view of it.
The quote is written after we have been on the roof and run the camera. It lists the new top, its material and size, the collar and cap, any framing or sheathing repair, and any work on the metal flue the camera has shown is needed. If the pipe is too damaged to keep, we tell you what replacing it would involve, since a new chase top on a failing flue only solves half the problem. Each item has its own price so you can see the full picture. For homes in a sale, the report and the quote are written so the buyer and seller can follow them. We replace chase covers across Cypress, Fountain Valley, Lakewood and Buena Park, and the months before the rain are the time to do it.
The Seymour Way Through a Job
Footage First
The flue is filmed before a fix is picked
Measured to Fit
Liners and caps sized from real dimensions
Scope on Paper
Each line priced and signed off before work
Frames You Keep
Still images stay attached to your report
Local pages for chimney chase cover
Pick a town to read how its chimneys, weather and building stock shape this job around Cypress.
Nothing on the list fits that spelling. Type the first few letters of the town, or send it through the form.
More From Seymour
Chimney Sweep
Creosote and soot brushed from the flue walls, with a camera look wherever the brushes reveal a gap, a chip or a loose tile.
Open service →Chimney Inspection
Firebox, flue, crown and cap examined at the NFPA 211 level your situation calls for, with camera footage whenever the tiles need reading.
Open service →Chimney Repair
Open mortar joints, spalled brick, cracked flue tiles and worn tops put right once we know what let the damage start.
Open service →Fireplace Inspection
Firebrick, hearth, damper and smoke chamber examined from inside the room, with the throat filmed where light alone falls short.
Open service →Fireplace Repair
Cracked firebrick, loose hearth slabs, failed refractory panels and seized dampers repaired so the opening holds heat where it belongs.
Open service →Chimney Level 2 Inspection
Video of each flue section from firebox to crown, with every finding tied to a timestamped frame in the report.
Open service →Chimney Cap Installation
Caps measured to the flue tile and fastened at the crown, keeping rain and nesting birds away from the liner below.
Open service →Chimney Flashing Repair
Step and counter flashing rebuilt where the chimney meets the shingles, so roof runoff stays outside the house framing.
Open service →Chimney Masonry Repair
Repointing, brick replacement and course resetting for stacks where weather has opened joints or flaked brick faces loose.
Open service →Chimney Rebuilds
Stacks that lean, crack through or lose their tiles taken down and rebuilt with new brick and a new flue inside.
Open service →Fireplace Cleaning
Ash, soot and stain removed from the firebox, glass doors and surround, leaving the opening ready for its next fire.
Open service →Gas Fireplace Cleaning
Burner ports, pilot hood and glass cleared of film and dust, then flame and venting checked against the unit's manual.
Open service →Gas Fireplace Repair
Ignition, valve, sensor and venting faults on gas fireplaces found with a meter, then fixed with parts listed for the model.
Open service →Fireplace Remodel
New facing, hearth and mantel planned around the firebox and flue you already have, or around an insert going in.
Open service →Fireplace Inserts
Wood and gas inserts set into existing fireboxes, each connected to a full-height stainless liner sized to the unit's outlet.
Open service →Pellet Stove Repair
Jammed augers, dead igniters, tired blowers and confused boards traced part by part with a meter and the stove's error log.
Open service →Wood Stove Repair
Door seals, glass, baffles, firebrick and stovepipe on wood stoves restored so the fire burns slow and the smoke goes up.
Open service →Gas Logs
Ceramic logs and a burner pan fitted to an existing wood firebox, with valve, venting and flue checked before first lighting.
Open service →Chimney Seismic Retrofit
Brick stacks braced, strapped or lowered and rebuilt lighter, chosen after we see how the chimney is tied to the house.
Open service →Chimney Crown Repair
Cracked or crumbling crowns sealed or recast so water stops reaching the brick and the outside of the flue tile.
Open service →Dryer Vent Cleaning
Lint cleared from the duct between the dryer and the outside hood, with airflow measured at the termination afterward.
Open service →Chimney Liner Installation
Cracked or shifted clay tiles bypassed with a stainless liner matched to what burns below it and run up to the crown.
Open service →Chimney Leak Repair
Drips, stains and wet firebox floors traced back to where the water first gets in, then closed at that point.
Open service →Chimney Waterproofing
Masonry repellent brushed or sprayed onto brick that has already been repointed and capped, so weather stops soaking the stack.
Open service →Chimney Damper Repair
Throat dampers that stick, rattle or no longer seal repaired or replaced, including a top-mounted damper where the frame has failed.
Open service →